BRAIN CryogenicsHome

BRAIN SMU MONITORING

Your vessels and alarms.
At a glance.

BRAIN SMU brings together your vessels, trends and alarms. See which installation needs attention and support your team with reports and targeted advice.

Find the vessel that needs attention

Supported by BRAIN Service · available 24/7

Can you find the deviation?Try the filters, open a vessel and view the trend. The short challenge helps you get started.

Try the monitoring yourself ↓
Try BRAIN's own SMU overview.Use the filters, open a vessel or try alarm history, reports and settings. You are working with example data.Open the demonstration in a larger view ↗

DOCUMENTATION FOR YOUR TEAM

Keep the manual close at hand.

Request the BRAIN SMU manual. BRAIN reviews your request and sends the appropriate documentation personally.

MULTIPLE PRODUCTS. ONE OVERVIEW.

From live readings to useful history.

BRAIN SMU collects data from connected vessel and piping controllers and presents it in its own browser interface.

Installation overview

Vessel cards show level, temperatures and state. Piping cards bring together temperature, requests, schedules and permission. Counters show which controllers are online, offline or need attention.

Search and status filters

Find the right controller or filter by All, Alarm, Warning, Offline and Filling. Switch quickly between a full overview and a focused selection.

Details and 24-hour trends

Open a card for readings, process state, communication and the available trend over the last 24 hours. Additional IO and sensor information supports investigation by BRAIN Service.

Alarms and event history

Active alarms and warnings are recognisable through both colour and text. Alarm history records activation and recovery as ON and OFF events, with the controller and time.

Alarm and recovery emails

With a mail server and recipients configured, the SMU can send alarm and recovery messages. Settings determine which notifications and repeat messages are sent.

Monthly reports

View a monthly report as HTML or PDF with the available measurement and alarm data. Email delivery and scheduled monthly emails are configurable functions.

HOW INFORMATION IS BUILT UP

Measure, collect and review.

The live card and history have the same source: data made available by the connected controller and touchscreen.

  1. 01

    Measure at the equipment

    The local controller provides readings, state, alarms and contact information.

    Source: controller and touchscreen
  2. 02

    Collect in SMU

    The server receives the messages and associates them with a recognisable controller card.

    Transfer through the configured network
  3. 03

    Record and review

    Recorded readings and alarm events form the basis for trends and reports.

    Available history and timestamps
  4. 04

    Follow up

    The user investigates a deviation and can discuss the data with BRAIN Service.

    Optional: configured alarm emails

History starts when the server begins recording data. N/A, offline status and missing readings are assessed accordingly. A report gives insight into the available data; it does not replace local checks at the equipment.

DAILY USE

From an overview to the right question.

  1. 01

    Start with the whole installation

    Check the counters and confirm that the expected controllers are present.

  2. 02

    Select a product

    Use the search or a status filter and open the corresponding card.

  3. 03

    Read the value and the trend

    Compare the state, alarm message and trend; check the local controller display if needed.

  4. 04

    Record the next step

    Use history and reports for assessment, maintenance or discussion with BRAIN Service.

NormalWarningAlarmFillingOffline

Colour supports the text. A filter or status card does not start filling and is not feedback of a physical valve position.

CONNECTIONS WITHIN THE INSTALLATION

From local controls to central information.

01

Measurements

Level, temperature and connected contacts.

Measurement data →
02

BRAIN controller

Firmware evaluates the process state and controls outputs.

Status ↔ commands
03

BRAIN controller

Local display, operation, settings and logging.

Data through the network →

Control takes place in the controller. In connected installations, the SMU can also coordinate requests and permissions between vessels and piping. Connections and enabling conditions are agreed for each installation.

Network and access

The dashboard is available on the local server display and through an approved browser within the configured network. Availability, user arrangements and any remote access are agreed with the site.

Permission and building signals

Connected installations exchange filling requests and piping permissions. Building contacts, alarm integration and operating conditions are configured and checked for the installation.

Information at the vessel.

See how the BRAIN controller display brings local measurements and controls together.

Discover the BRAIN controller →

BRAIN CRYOGENICS

Made in the Netherlands.
Expertise in-house.

We develop and manufacture our own cryogenic systems in the Netherlands. We bring that expertise to the selection, layout and support of your installation.

PERSONAL CONTACT

Discuss your application

Tell us what your team is dealing with. We work with you to find a practical solution.

24/7 service · +31 6 41 600 600
Email BRAIN Cryogenics
BRAIN DOCUMENTATION

Request the manual

Your details are sent to info@brainbv.nl and used to answer your request. This does not subscribe you to a newsletter. BRAIN reviews the request before sending the manual.